Technoview® UFH Calibrator Set is a set of plasma-derived calibration samples with unfractionated heparin (UFH) concentrations ranging from ~0-1.4 IU/ml. The set can be used for establishing a standard curve in research measurements of heparin. It is optimized for use with anti-Xa chromogenic assays and is frequently used in conjunction with the Technoview® UFH low and high controls in the Technochrom® anti-Xa chromogenic assay.
Reagent | Size | Description |
CAL 1 | 1 x 1 mL | Technoview® UFH Calibrator 1, human plasma, lyophilized, 0.00 IU/mL UFH |
CAL 2 | 1 x 1 mL | Technoview® UFH Calibrator 2, human plasma, lyophilized, ~0.35 IU/mL UFH |
CAL 3 | 1 x 1 mL | Technoview® UFH Calibrator 3, human plasma, lyophilized, ~0.70 IU/mL UFH |
CAL 4 | 1 x 1 mL | Technoview® UFH Calibrator 4, human plasma, lyophilized, ~1.05 IU/mL UFH |
CAL 5 | 1 x 1 mL | Technoview ® UFH Calibrator 5, human plasma, lyophilized, ~1.40 IU/mL UFH |
Please consult the lot specific batch table provided with the calibrators for the exact concentrations in IU/mL of each calibrator.
Stability after reconstitution: 18-25°C (open vial) / 48 hours, 2-8°C (closed vial) / 7 days, -20°C / 1 month.
5 x 1 ml vials with a range of unfractionated heparin (UFH) concentrations:
Calibrators are lyophilized and prepared from pooled human citrated plasma supplemented with different concentrations of unfractionated heparin. The plasma contains stabilizers but no bactericide additives. It is calibrated against the 5th International Standard preparation for UFH 97/578.
Heparin is a widely used antithrombotic agent that can be administered via an intravenous or subcutaneous route. It is naturally occurring and typically derived from bovine or porcine tissue. The anticoagulant effect of this sulfated glycosaminoglycan results from its binding to antithrombin (AT), the major inhibitor of the coagulation cascade. Binding induces a conformational change in the AT molecule, which greatly accelerates the AT inhibition of several coagulation proteases. The accelerated inhibition of thrombin and Factor Xa by heparin is the primary basis for its anticoagulation properties.
Two forms of heparin are used therapeutically: unfractionated heparin (UFH), with an average molecular weight (MW) of 15,000 and low molecular weight heparin (LMWH), with a MW between 4,000 and 6,500. The lower MW results in LMWH acting primarily on Factor Xa, whereas UFH efficiently inhibits both thrombin and Factor Xa. Both heparin forms should be monitored. UFH can be measured with an aPTT or an anti-Xa chromogenic assay while LMWH should be measured using and anti-Xa chromogenic assay. Note that this calibrator set is for research use only in the US and Canada.