$0.00
The TECO® Cyprinid Vitellogenin ELISA kit is a sensitive sandwich enzyme linked immunosorbent assay for the quantitative determination of vitellogenin in serum, WBH and mucus of cyprinids.
Vitellogenin determination is one of the core endpoints in screening and testing for endocrine disrupting chemicals standardized in the OECD Guidlines for the testing of chemicals for estrogenic activity:
Vitellogenin determination is used in ecotoxicological studies to determine estrogenic compounds in the water.
Vitellogenin levels can be used to determine the sex and the sexual maturation of fish.
Range: 0-35 ng/ml
Sensitivity: < 0.1 ng/ml
Incubation time: 4.0 hours
Sample Volume: 50 µl
Sample Preparation:
Reference Values:
Stimulation Studies using estradiol (E2), Ethinyl-Estradiol (EE2,) Bisphenol A show clear increases in Vitellogenin levels in serum, WBH and mucus.
Symbol | Description | Format |
---|---|---|
1 | 96-well plate coated with cypVTG Antibody 12 break apart strips of 8 wells (12 x 8 in total), in a frame. Ready to use. |
1 plate |
S | Standard Stock lyophilized 17.5 ng |
2 x |
C1 | Control C1 lyophilized. Concentration: see Data Sheet. |
2 x |
C2 | Control C2 lyophilized Concentration: see Data Sheet. |
2 x |
2 | Wash Buffer 50x Dilute 1:50 with deionized water. |
1 x 30 ml |
3 | Dilution Buffer Ready to use. |
1 x 55 ml |
4 | Matrix Solution Ready to use. |
1 x 7 ml |
5 | Biotinylated Antibody (Biotin-AB) Ready to use. |
1 x 12 ml |
6 | Streptavidin Peroxidase Conjugate (SA- HRP Conj) Ready to use. |
1 x 12 ml |
7 | TMB Substrate Ready to use. |
1 x 12 ml |
8 | Stop Solution – 1 M HCI 1 M hydrochloric acid. Ready to use. |
1 x 12 ml |
I | Kit Instructions | 1 x |
Is there an ultrasensitive Perch ELISA available? Are there any suggestions for modifying the Perch ELISA if lower VTG values need to be detected in mucus?
The TECO® Perch Vitellogenin ELISA is the only commercially available ELISA for Perch/Perciformes. At the moment, there is not enough demand for an ultra-sensitive protocol. One option using the current protocol is to lower the dilution factor from 1:10 (50μL sample + 450μL extraction buffer) to 1:6 (50μL sample + 250μL extraction buffer). In development, this has been shown to increase the sensitivity of the assay appropriately.
How do I know mucus samples are not cross-contaminated by a nearby fish when I am collecting my samples?
It is recommended that mucus under the gill be swabbed, if cross contamination from nearby fish is a concern. This can be a concern with net fishing, where high- and low- level vitellogenin fish are in close proximity to each other.
How do I know mucus samples are not cross-contaminated with other environmental substances that may interfere with the assay and affect my results?
The antibodies used in the assays are very specific and do not recognize other components. Furthermore, the extraction buffer (500μL) used to dilute the mucus collected with the swab has a dilution effect that will dilute out a rare occurrence of an environmental contaminant. In development of the assay, aquarium water was used as a negative control and no contamination from the mucus samples was detected in comparison to the aquarium water.
Is it necessary to correct mucus (or blood, WBH) VTG against the protein alone?
While this is not necessary, the extraction buffer used in collecting mucus and the dilution buffer used in diluting blood and WBH are protein-free so they do allow for an easy parallel determination of proteins.
What is the calibrator material?
The calibrator material is biologic and not recombinant. It is prepared from serum that has been run through a column and separated via affinity chromatography. It is extensively validated and characterized using immunohistochemical staining, Western blot and SDS PAGE technology.
What is the composition of the matrix solution and what is its purpose in the assay?
The exact composition is proprietary information. The solution is responsible for activating the full reactivity of the plates.
What is the composition of mucus extraction buffer and sample dilution buffer?
The exact composition is proprietary information but both are protein-free solutions optimized for the assay.
What are the test strips coated with?
A polyclonal (affinity purified) antibody to vitellogenin.
What dilution should be used to prepare samples?
The best sample dilution will vary based on type of sample (blood, homogenate or mucus), species and exposure to test compound(s). Refer to the package insert and/or the Vitellogenin ELISA Crossreactivity chart for suggested dilution ranges. During assay evaluation/validation, it is recommended that several dilutions, based on the recommended range, be tested initially using a subgroup of samples. The results from assaying the subgroup at several dilutions can then be used to determine the best dilution for the rest of your samples based on your experimental design.
Can serum or plasma samples be used in the ELISA?
Yes, in all assays. Homogenate epidermal mucus samples may also be used.
What are the advantages of performing ELISA rather than molecular testing?
Molecular testing reflects the gene expression whereas ELISA assays detect the product, or actual effect, of this expression. Additionally, molecular assays tend to be time-consuming, costly and more sensitive to technique variables such that they require special laboratories with well-trained personnel.
How soon after exposure will the VTG protein be detected in mucus compared to blood/homogenate and compared to the detection of vtg gene expression?
This will vary depending on the substance and species, but in general, the VTG protein (gene expression) can be detected in mucus 48 hours after exposure to 2.5 ng/L EE2.
What are the advantages of using mucus rather than blood or whole body homogenate?
Mucus collection is non-invasive and non-destructive. It can be easier to collect from smaller fish. Collectingmucus does not require sacrificing the fish which means repeat sampling allows for studying induction kineticsby individual. Repeat sampling also allows for pre-exposure testing, making it possible to assess handling(stress)-related impacts on VTG induction. Additionally, research indicates the vitellogenin protein may be morestable in mucus. In blood, the vitellogenin protein can be especially prone to proteolytic cleavage.
The TECO® Cyprinid Vitellogenin EIA Kit is a 96 well immuno-capture ELISA product. Serum, WBH and mucus samples are incubated with the vitellogenin specific antibody coated microtiter plate. After unbound material is washed out, a polyclonal biotinylated antibody binds to the vitellogenin. In the following incubation step, a streptavidin-peroxidase conjugate binds to the biotinylated antibody. In the final substrate reaction, the color development is directly proportional to the amount of vitellogenin in the sample.
All determinations (standards, controls and samples) should be assayed in duplicate. When performing the assay, the standards, controls and samples should be pipetted as fast as possible (<15 minutes).
To avoid distortions due to differences in incubation times, HRP conjugate, substrate solution and stop solution should be added to the plate in the same order and with the same time interval as the samples. A multichannel pipette is essential.
Allow all reagents to stand at room temperature (20–25 °C) for at least 30 minutes. During all incubation steps, plates should be sealed with the adhesive foil or a plastic cover. For light protection, incubate in a dark chamber or cover plate with aluminum foil.
In oviparous animals, vitellogenin (VTG) is an estrogen induced yolk precursor protein mainly synthesized in the liver to be deposited in the maturing oocytes, where it is split in the yolk proteins lipovitellin 1, lipovitellin 2 and phosvitin. These yolk proteins serve as nourishment storage for the developing embryos. Non-physiological induction of vitellogenin in males or in juvenile fish is thought to indicate an estrogen mediated endocrine disruption. Therefore VTG determination is one of the core endpoints in screening and testing for endocrine disrupting chemicals standardized in the OECD Guidelines for the testing of chemicals for estrogenic activity. Normally vitellogenin is measured in blood samples or whole body homogenate (WBH) – both sample types require invasive and destructive treatment of the fish. Blood is difficult to collect, in particular where very small fish are concerned, or in approaches where the animals must survive sampling. This is particularly important in field monitoring in order to avoid impact on the population under investigation. Recently several cell types have been shown to produce VTG after estrogen stimulation, including those of the epidermal mucosa. Even though the VTG concentration in the skin mucus is an order of magnitude lower than in blood serum or in body homogenates (containing liver tissue), the skin mucosa is very well suited as a matrix to determine exogenous VTG induction caused by environmental chemicals with affinity to estrogen receptors. By using a highly sensitive ELISA in combination with an unique sampling and extraction system the determination of mucosa born VTG determination has the following advantages: