Primary Hemostasis/Platelet

Atlas PST

Stays Medical Corporation’s Atlas Platelet Strength Test (PST) measures platelet functional forces and aggregation via micro-sensors and video microscopy on an automatically loaded microfluidic cartridge under flow conditions.

The Atlas PST provides real-time information on an individual’s true platelet functionality rapidly and comprehensively.  The innovative microfluidic chip utilized by the Atlas PST delivers higher quality test results than other platelet analyzer without a complicated pre-analytical test preparation procedure.  This allows for a more complete understanding of bleeding and the primary hemostasis system.

Platelet Micro Force Technology

Stasys force sensor  Stasys Sensor with Platelet

The Atlas PST measures multiple physical properties of collagen and shear force stimulated platelets assessment throughout the formation of the platelet plug.

The groundbreaking technology in the Atlas PST is the measurement of platelet forces generated on a nano-scale over time on a fixed block and flexible post method.  In this method, the sample is flowed over a collagen coated array of microsensors.  A detector measures both the real size of the platelet aggregate, but also the micro forces being generated by the active, contractile platelets on the flexible post.

Microfluidic Cartridges

SPS assays are performed in collagen coated microfluidic cartridges designed for maximal precision and accuracy.  Preparing the blood sample is as simple as adding blood to a syringe and screwing into the cartridge.

stasys card

Product Method / Application Packaging Use ? Catalog #

Atlas PST

Platelet Micro Force Generation and Aggregometry Instrument RUO SPS-004-V1-C

Atlas Micro Force Cartridge

Platelet Micro Force Generation and Aggregometry Kit RUO STC-004-V13-10

T-TAS® 01

The Total Thrombus formation Analysis System (T-TAS®) is an automated microchip flow chamber system used to quantify the process of thrombus formation under blood flow conditions.  The T-TAS® 01 enables the ex vivo evaluation of overall hemostatic ability that more closely resembles in vivo conditions than other methodologies.

View the recording of Shearly you can’t be serious! T-TAS® 01 for Total Platelet Function Testingto learn about the performance and utility of the T-TAS®01 assays. 

Technology Behind T-TAS

The T-TAS® 01 measures multiple integrated physical and physiologic properties of collagen- and shear force-stimulated platelets through the formation of the platelet plug during primary hemostasis.  The T-TAS® 01 measures temporal changes in the pressure differential required to flow a specific volume of whole blood through the test flow channel.  In this method, the patient sample is flowed through the collagen-coated test channels at a constant rate.  As the platelets adhere, activate, and aggregate to the walls of the microfluidic channels and to other platelets, the channels begin to occlude.  The pressure required for the same volume of blood to flow through the occluding channel is measured in real-time by highly sensitive pressure sensors.

T-TAS Consumables

PL Chip
The PL Chip for T-TAS® 01 is designed for the analysis of primary hemostatic dysfunction and to monitor anti-platelet therapeutics in patients.  Each individual test contains 26 collagen-coated capillary channels in parallel for internal quality control purposes.  Each chip is sufficient to run two samples. The BAPA tube is intended to be used for the collection, transport, and storage of blood specimens for use with the PL Chip and T-TAS® 01 system.  BAPA (Benzylsulfonyl-1-D-arginyl-prolyl-4-amidobenzylamide) is an inhibitor of both Factor Xa and thrombin (Factor IIa).  This allows for complete anticoagulation of blood without interfering with physiological levels of calcium ions, unlike sodium citrate.
The AR Chip for T-TAS® 01 is designed to study the complex web of biochemical and biophysical reactions that occur between primary hemostasis and the coagulation cascade system at the site of vascular injury.  Under flow conditions, platelet activation and the coagulation processes are dynamically intertwined with one another and are affected by platelets, coagulation factors, and their various inhibitors and activators.

The AR Chip is RUO in the US and Canada.

The HD Chip for T-TAS® 01 is designed to study primary hemostasis, much like the AR Chip, but under thrombocytopenic or hemi-diluted sample conditions.  The special design of the HD Chip allows the T-TAS® 01 to be effective with as few as 10,000 platelets per microliter.

The HD Chip is RUO in the US and Canada.

Product Method / Application Packaging Use ? Catalog #

Anti-Sedimentation Solution

Microfluidic Clot Detection Vial/2 mL RUO NS0001

HD Chip for T-TAS® 01

Microfluidic Clot Detection Box/20 Chips RUO 19002

CaCTI Reagent for T-TAS01

Microfluidic Clot Detection 1 Tube (0.4 mL) RUO 19004

AR Chip for T-TAS01

Microfluidic Clot Detection Box/20 Chips RUO 19001

AR Chip and HD Chip Reservoir to T-TAS01

Microfluidic Clot Detection Box/100 Reservoir Sets RUO 19003

T-TAS01

Microfluidic Clot Occlusion Instrument IVD 18001

PL Chip Reservoir Set

Microfluidic Clot Occlusion Box/100 Reservoir Sets (100 Total Assay Runs) IVD 18003

BAPA Anticoagulant Blood Collection Tube

Anticoagulant Box/50 x3mL collection tubes IVD 18004

PL Chip

Microfluidic Clot Occlusion Box/20 Chips (40 Total Assay Runs) IVD 18002

Mineral Oil, Light

Bottle/1L RUO 330779-1L

Multiplate® 5.0

platelet adhesion activation aggregation

Thrombocytes (platelets) play a central role in the primary as well as in the secondary hemostasis. Apart from this task they are also deeply involved in wound healing and blood vessel dependent tumor metastasis. Read more…

The Multiplate® has been discontinued in North America.

Product Method / Application Packaging Use ? Catalog #

BAPA Anticoagulant Blood Collection Tube

Anticoagulant Box/50 x3mL collection tubes IVD 18004

Multiplate® Analyzer

Platelet Aggregometry Instrument RUO MP0010 – Discontinued

Multiplate® Electronic pipette w/holder

Platelet Aggregometry Box / 1 pipette RUO MP0030 – Discontinued

TRAP-6

Platelet Aggregometry Vial/1x5mg RUO ABP-TRA-1 – Discontinued

Collagen (Type 1 Calf Skin, 1.9mg/mL)

Platelet Aggregometry Box/3x0.5mL IVD ABP-COL-T1 – Discontinued

Arachidonic Acid (5mg/mL)

Platelet Aggregometry Box/3x0.5mL IVD ABP-ARA-1 - Discontinued

Ristocetin (Ristocetin Sulfate)

Platelet Aggregometry Box/6x15mg RUO 100RISTO15

ADP (0.2mM)

Platelet Aggregometry Box/3x0.5mL IVD ABP-ADP-1 – Discontinued

Haematex SOLCOLL (Soluble Collagen Dispersion)

ELISA Kit/6x8ml RUO X9315

Haematex Collagen (Equine Fibrous Type I/III)

ELISA Vial/1gm RUO X9310

Hart Biologicals Collagen Reagent

Platelet Aggregometry Vial/1x1ml RUO HB‐5515‐FG – Discontinued. Replacement: ABP-COL-T1

Hart Biologicals Collagen

Platelet Aggregometry Vial/1x1ml RUO HB‐5503‐FG – Discontinued. Replacement: ABP-COL-T1

Multiplate® Test Cells

Platelet Aggregometry Bag/6x10pieces RUO 08128847001 – Discontinued

Multiplate® Mini Test Cells

Platelet Aggregometry Bag/6x10pcs RUO MP0028 – Discontinued

Multiplate® ASPItest, 3x1ml

Platelet Aggregometry Kit/3x1ml RUO 08115826001 - Discontinued

Multiplate® ASPItest

Platelet Aggregometry Kit/1x1ml RUO MP0191 – Discontinued. Replacement: MP0210

Multiplate® ASPItest

Platelet Aggregometry Bag/1ml + 5 micro test tubes RUO MP0110 – Discontinued. Replacement: MP0210

Multiplate® ASPItest Aliquot Vials

Platelet Aggregometry Box/100pcs RUO 06675662190 – Discontinued

Multiplate® ADPtest

Platelet Aggregometry Kit/1x1.0ml RUO MP0192 – Discontinued. Replacement: MP0220

Multiplate® ADPtest, 3x1ml

Platelet Aggregometry Kit/3x1ml RUO 08115761001 – Discontinued. Replacement: HB-5502-FG

Multiplate® ADPtest

Platelet Aggregometry Bag/1ml + 5 micro test tubes RUO MP0120 – Discontinued. Replacement: MP0220

Multiplate® ADPtest Aliquot Vials, 100pcs

Platelet Aggregometry Box/100pcs RUO 00675689190 – Discontinued

Multiplate® COLtest, 3x1ml

Platelet Aggregometry Kit/3x1ml RUO 08115842001 – Discontinued. Replacement: HB‐5503‐FG

Multiplate® COLtest

Platelet Aggregometry Kit/1x1.0ml RUO MP0193 – Discontinued. Replacement: MP0230

Multiplate® COLtest

Platelet Aggregometry Bag/1ml + 5 micro test tubes RUO MP0130 – Discontinued. Replacement: MP0230

Multiplate® COLtest Aliquot Vials, 100pcs

Platelet Aggregometry Box/100pcs RUO 06675697190 – Discontinued

Multiplate® TRAPtest, 3x1ml

Platelet Aggregometry Kit/3x1ml RUO 08116679001 – Discontinued. Replacement: ABP-TRA-1

Multiplate® TRAPtest

Platelet Aggregometry Kit/1x1.0ml RUO MP0195 – Discontinued. Replacement: MP0250

Multiplate® TRAPtest

Platelet Aggregometry Bag/1ml + 5 micro test tubes RUO MP0150 – Discontinued. Replacement: MP0250

Multiplate® TRAPtest Aliquot Vials, 100pcs

Platelet Aggregometry Box/100pcs RUO 06675727190 – Discontinued

Multiplate® RISTOtest, 3x1ml

Platelet Aggregometry Kit/3x1ml RUO 08116644001 – Discontinued. Replacement: HB-5508-FG

Multiplate® RISTOtest

Platelet Aggregometry Bag/1ml RUO MP0194 – Discontinued

Multiplate® RISTOtest

Platelet Aggregometry Kit/1ml + 5 micro test tubes RUO MP0140 – Discontinued. Replacement: MP0240

Multiplate® RISTOtest Aliquot Vials, 100pcs

Platelet Aggregometry Box/100pcs RUO 06675719190 – Discontinued

Multiplate® Prostaglandin E1 Reagent, 3x1ml

Platelet Aggregometry Kit/3x1ml RUO 08115982001 - Discontinued

Multiplate® Prostaglandin E1

Platelet Aggregometry Kit/1ml RUO MP0540 – Discontinued

Multiplate® Hirudin Blood Tube (Double-Wall) 50x3ml

Platelet Aggregometry Tray/50x3ml RUO 08128812001 – Discontinued

Hirudin blood tube

Platelet Aggregometry Kit/50x1.6ml RUO 04.1959.001 – Discontinued

Multiplate® Prostaglandin E1

Platelet Aggregometry Kit/1ml + 5 micro test tubes RUO MP0160 – Discontinued

Multiplate® Prostaglandin E1 Reagent, 100pcs

Platelet Aggregometry Box/100pcs RUO 06675735190 – Discontinued

Multiplate® Liquid Controls

Platelet Aggregometry Set/10 LQC RUO 08115966001 – Discontinued

Multiplate® ASA Reagent, 3x1ml

Platelet Aggregometry Kit/3x1ml RUO 08115796001 – Discontinued

Multiplate® ASA Reagent Aliquot Vials, 100pcs

Platelet Aggregometry Box/100pieces RUO 06675743190 – Discontinued

Multiplate® ASA Control

Platelet Aggregometry Kit/1ml + 5 micro test tubes RUO MP0170 – Discontinued. Replacement: MP0270

Multiplate® PAR-4 test

Platelet Aggregometry Bag/1ml + 5 micro test tubes RUO MP0549 – Discontinued

Multiplate® vWF Reagent

Platelet Aggregometry Bag/1ml RUO MP0548 – Discontinued

Multiplate® GpIIb/IIIa Antagonist Reagent

Platelet Aggregometry Kit/3x0.5ml RUO 08115869001 – Discontinued

Multiplate® GpIIbIIIa Antagonist

Platelet Aggregometry Kit/1x0.5ml RUO MP0520 – Discontinued. Replacement: MP0280

Multiplate® ASA Control

Platelet Aggregometry Bag/1ml RUO MP0510 – Discontinued. Replacement: MP0270

NaCl/CaCl2

Platelet Aggregometry Bag/10x5ml RUO 08115974001D – Discontinued

Multiplate® Hirudin Blood Tube (Double-Wall)

Platelet Aggregometry Bag/10x3ml RUO MP0601 – Discontinued. Replacement: MP0600

Multiplate® TI – Thrombin Inhibitor Blood Collection Tube

Platelet Aggregometry Bag/10x1.25ml RUO MP0631 – Discontinued

Multiplate® Diluent Pre-heating Tube

Platelet Aggregometry Box/10pcs RUO 006675654001 – Discontinued

Multiplate® Electronic Pipette Tips, 1000pcs

Platelet Aggregometry Box/1000pcs RUO MP0040 – Discontinued

Multiplate® Electronic Pipette Tips, 96pcs

Platelet Aggregometry Box/96pieces RUO MP0050 – Discontinued

Multiplate® Electronic Pipette Tips, 10x96pcs

Platelet Aggregometry Box/10x96pieces RUO MP0050-10 – Discontinued

Multiplate® Electronic Pipette Filters

Platelet Aggregometry Box/5pcs RUO MP0033 - Discontinued

Multiplate® Electronic Pipette Filters

Platelet Aggregometry Box/50pcs RUO MP0033-50 - Discontinued

Multiplate® Electronic Pipette Filters with filter forceps

Platelet Aggregometry Box/5+1pcs RUO 006675620001 - Discontinued

Multiplate® Electronic Pipette Holder

Platelet Aggregometry Part RUO MP0383

Multiplate® Electronic Pipette Holder

Platelet Aggregometry Part RUO

Multiplate® Electronic Pipette Holder

Platelet Aggregometry Part RUO MP0380 - Discontinued

Multiplate® Electronic Pipette Cable

Platelet Aggregometry Part RUO MP0390 - Discontinued

Multiplate® Electronic Pipette Extended Cable

Platelet Aggregometry Part RUO MP0385 - Discontinued

Multiplate® Sensor Cables

Platelet Aggregometry Box/7pcs RUO 006675204001 - Discontinued

Multiplate® Reagent Rack

Platelet Aggregometry Rack RUO MP0370 - Discontinued

Cherry Professional Compact Keyboard G84-4100 for use with Multiplate®

Box/1 pc RUO MP0441-EU - Discontinued

Cherry Professional Compact Keyboard G84-4100 Cover for use with Multiplate®

Box/1 pc RUO MP0442 - Discontinued

Multiplate® Mouse

Box/1 pc RUO MP0032 – Discontinued

Acer V176L LCD Monitor

Box / 1 monitor RUO MP-MONITOR – Discontinued

Printer

Box / 1 printer RUO PRINTER – Discontinued